CVE-2025-40945

A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.

No Active Exploit Signals
CVSS Base Score
6.7
MEDIUM
Exploitability:0.8
Impact Score:5.9
Executive Threat Verdict
Evaluating...
Evaluating Threat Landscape...
Assessing known weaponization, exploitation telemetry, and federal advisories.
Attack Surface
—
Authentication
—
Weaponization
—
SSVC Action
—

Weaknesses (CWE)

CWE-426 ↗CWE-426: Untrusted Search Path

Affected Products & Versions

Vendor Product Affected Versions
Siemens COMOS V10.4.5 0 < V10.4.5.0.2 (affected)
Siemens COMOS V10.6 0 < V10.6.1 (affected)
Siemens Designcenter NX 0 < V2512.7000 (affected)
Siemens Simcenter 3D 0 < V2512.7000 (affected)
Siemens Simcenter Femap V2506 0 < V2506.0003 (affected)
Siemens Simcenter Femap V2512 0 < V2512.0002 (affected)
Siemens Simcenter Nastran 0 < V2606 (affected)
Siemens Simcenter STAR-CCM+ 0 < V2606 (affected)
Siemens Solid Edge SE2025 0 < V225.0 Update 13 (affected)
Siemens Solid Edge SE2026 0 < V226.0 Update 04 (affected)
Siemens Teamcenter Visualization V2412 0 < V2412.0012 (affected)
Siemens Teamcenter Visualization V2506 0 < V2506.0009 (affected)
Siemens Teamcenter Visualization V2512 0 < V2512.2605 (affected)
Siemens Tecnomatix Plant Simulation V2404 0 < V2404.0022 (affected)
Siemens Tecnomatix Plant Simulation V2504 0 < V2504.0010 (affected)
Siemens Tecnomatix Process Simulate 0 < V2606 (affected)