Vulnerability Intelligence Report
RPC session pool exhausted by unfinished fragmented requests
CVE-2026-127124
P-Net before 1.0.4 keeps the RPC session that is allocated for a fragment of a request with an unknown activity UUID, without a timeout, when the rest of the request never arrives. A session that does not get an Application Relationship is also kept after the response. Repeated fragments or requests with different activity UUIDs exhaust the available sessions, one UDP packet per session. Once they are exhausted the device no longer answers a Connect request until it is restarted. An unauthenticated attacker with ADJACENT network access can use this to cause a denial of service.
No Active Exploit Signals
CVSS Base Score
7.1
HIGH
Executive Threat Verdict
Evaluating...
Evaluating Threat Landscape...
Assessing known weaponization, exploitation telemetry, and federal advisories.
Attack Surface
—
Authentication
—
Weaponization
—
SSVC Action
—
Weaknesses (CWE)
CWE-772 ↗CWE-772 Missing Release of Resource after Effective Lifetime
Affected Products & Versions
| Vendor | Product | Affected Versions |
|---|---|---|
| RT-Labs | P-Net | 0 < 1.0.4 (affected) |
References & Technical Advisories
No reference links found.
Threat Intelligence Signals
GitHub Advisory
Identity & Timeline
| Status | PUBLISHED |
| Assigning Authority | RT-Labs AB · Vendor · Sweden |
| Reserved | 2026-11-12T15:30:49 |
| Published | 2026-11-13T13:25:33 |
| Last Updated | 2026-11-13T20:05:34 |
Community Chatter & Buzz